Electrical design and control panels
Schematics, I/O lists and PLC control panels, designed, assembled, wired and tested for your machine or process.
Animations are off because your device is set to reduce motion.
We deliver the electrical and control side of machines and process lines: design, panels, programming, testing, commissioning and support.
Schematics, I/O lists and PLC control panels, designed, assembled, wired and tested for your machine or process.
Clear, commented PLC logic and HMI screens for Siemens, Schneider Electric, Delta, LS Electric and Wecon, in Arabic, English or both.
Complete control systems for filling, labeling, printing, washing and test machines: PLC, HMI, VFDs, stepper and motion control.
Keep a good machine and replace its old controls: new PLC, HMI, drives and motion control, documented and tested, with a planned changeover.
Control of pasteurization, sterilization, cooking, coating, CIP, batching and dosing, with recipes, interlocks and data logging.
SCADA screens, alarms, recipes, reports and traceability, so you can see the process and show what was produced.
I/O and loop checks, interlock tests, start-up and tuning, for systems we build and for machines and lines supplied by others.
Breakdown troubleshooting, program changes, preventive maintenance, operator training and help sourcing spare parts in Egypt.
Projects
Real machines and real photos from our projects. Client names are withheld.

Food and beverage2026


How automation works
Sensors measure, the PLC decides, the HMI keeps people in the loop and the actuators act. Then it starts again, many times a second.
Signal types shown are typical examples.
Scope options
Design, panel, PLC and HMI programs, testing and commissioning, delivered by one team.
You build the panel or the machine. We write the program, design the screens or produce the drawings.
For equipment supplied by others: instrument and I/O checks, logic tests, start-up and punch-list closure.
Troubleshooting, program changes, preventive maintenance and training, on terms agreed in writing.
From survey to handover
Six steps from the first visit to a running machine. You talk to the same engineers throughout.
We see the machine or line, read the nameplates and drawings, and agree what the system must do.
You receive a written scope and quote. Once agreed, we produce the schematics, I/O list and bill of materials.
We assemble and wire the control panel, write the PLC program and design the HMI screens.
Wiring checks, I/O simulation and an HMI walk-through before anything reaches your floor.
I/O and loop checks, interlock tests, start-up and tuning with your operators.
As-built drawings, operator training and follow-up support when you need changes.
Frequently asked questions
Send a short description and a few photos. An engineer will review it and reply with questions or a quote.